IDtech Controllers
Stand Alone Controllers
R.A.U.
Remote Access Unit
- 12 or 220 volts
- With or without battery
- Controls up to two read heads
- Controls one inward/outward door or two inward door
- 2 TTL inputs for iso (clk, dat) or Wiegand (D0, D1) format
- 2 leds/head and 1 beeper/head
- 4 voltage-free inputs (Expandable to 8)
- 2 relay outputs : NO, NC (Expandable to 8)
- Storage capacity (contact us)
4 Inputs/4 Outputs
- Expansion board for R.A.U (4 inputs / 4 relays)
R.A.U. Twin
Remote Access Unit Twin
- 12 or 220 volts
- With or without battery
- Controls up to 4 read heads
- Controls two inward/outward door or four inward door
- 4 TTL inputs for iso (clk, dat) or Wiegand (D0, D1) format
- Controls 2 leds/head and 1 beeper/head
- 8 potential-free inputs (Expandable to 16)
- 4 NO, NC relay outputs (Expandable to 16)
- Storage capacity (contact us)
4 Inputs/4 Outputs
- Expansion board for R.A.U Twin (4 inputs / 4 relays)
R.T.U.
Remote Time Unit
- 12 or 220 volts
- LCD 4 lines of 40 characters
- back lighted - 16 keys keyboard
- Rétro éclairage
- 4 Leds
- Beeper
- Storage capacity (contact us)
R.S.U.
Remote Security-box Unit
- 12 or 220 volts
- 8 voltage-free inputs (expandable to 32)
- 8 output relays NO/NC (expandable to 32)
- No read head connection
- Maximum 3 I.O.E. options
- Storage capacity (contact us)
R.L.U.
Remote Lift Unit
- 8 floors management
- Expandable to 16,24 or 32 floors
- Maximum 3 I.O.E. options
- Storage capacity (contact us)
I.O.E.
In Out Extension
- 8 inputs / 8 relays expansion module for R.S.U. and R.L.U.
Standard Multi-reader Controller platform (request Local Units)
R.C.P. /b4
Remote Controller Platform bus 4
- Manage up to 4 local units using RS 485 bus.
- Manage up to 8 read heads
- Storage capacity (contact us)
R.C.P. /m8
Remote Controller Platform Mux 8
- Manage up to 8 local units using point to point connection
- Manage up to 16 read heads
- Storage capacity (contact us)
R.C.P. /b10
Remote Controller Platform bus 10
- Manage up to 10 local units using RS 485 bus.
- Manage up to 20 read heads
- Storage capacity (contact us)
High Capacity multi-reader controller platform (request local Units)
R.C.U. /m8
Remote Controller Unit Mux 8
- Manage up to 8 local units using point to point connection
- Manage up to 16 read heads
- Storage capacity (contact us)
R.C.U. /b10
Remote Controller Unit bus 10
- Manage up to 10 local units using RS 485 bus.
- Manage up to 20 read heads
- Storage capacity (contact us)
R.C.U. /m16
Remote Controller Unit Mux 16
- Manage up to 16 local units using point to point connection
- Manage up to 32 read heads
- Storage capacity (contact us)
Local Units for R.C.P. /xx or R.C.U. /xx
L.A.U.
Local Access Unit
- Maximum 2 reading heads
- 2 TTL inputs for iso (clk, dat) or Wiegand (D0, D1) format
- 2 leds/head and 1 beeper/head
- 4 voltage-free inputs(Expandable. to 8)
- 2 relay outputs : NO, NC (Expandable to 8)
L.T.U.
Local Time Unit
- LCD 4 lines of 40 characters
- Back lighted
- 16 keys keyboard
- 4 Leds
- Beeper
L.S.U.
Local Security-box Unit
- 8 voltage-free inputs (expandable to 32)
- 8 output relays NO/NC (expandable to 32)
- No read head connection
- Maximum 3 I.O.E. options
I.O.E.
In Out Extension
- 8 inputs / 8 relays expansion module for R.S.U. and R.L.U.
Power Supply
B.P.S. 4A
Back-up Power Supply 4A
- Power backup for R.C.P. / b4 and R.T.U.
B.P.S. 10A
Back-up Power Supply 10A
- Power backup for R.C.P/b10, R.C.P/m8, R.C.U/m8, R.C.U/b10 and R.C.U/M16
C.P.S. 4A
Complementary Power Supply 4A
- Alimentation 220 volts additionnelle pour R.C.P./b4
C.P.S. 10A
Complementary Power Supply 10A
- Alimentation 220 volts additionnelle pour R.C.P/b10, R.C.P/m8, R.C.U/m8, R.C.U/b10 et R.C.U/M16.